Testisampula: isilawuli sesithombe(JL-207C), zungeza i-receptacle(JL-240TLXA)
Inombolo yomthetho: JL-240TLXA, JL-207C
Isilinganiso: 480VAC, 15AMP
Ukuhlolwa Kuceliwe: Ukuhlolwa kwe-IPX5
Indlela Yokuhlola (izindinganiso): ngokwemfuneko yeklayenti futhi ubhekisele ku-IEC 60529+A1:1999+A2: 2013/EN 60529:1991+A1:200+A2:2013 isigatshana 14.2.5
UkuhlolaLi-laboratory: I-SGS-CSTC Standards Technical Services(Shanghai) Co., Ltd.
Usuku lokuhlolwa olwenziwe: 2017-3-30 2017-4-1
Idethi yokwamukelwa kwesampula: 2017-03-30
Tumphumela: dlula
Cukufakwa: isampula elithunyelwe lithobelana nezidingo ze-IPX5
Sebenzisa isimo
Ukuhlola kwenziwa ngokufafaza indawo ebiyelwe kuzo zonke izikhombisi-ndlela ezisebenzisekayo ngokugeleza kwamanzi kusuka kubhobho yokuhlola evamile njengenhlanzi yesimo sokuhlola.
Isimo okufanele sibhekwe yilesi:
- ububanzi bangaphakathi bombhobho: 6.3 mm;
-izinga lokulethwa :12.5 L/min + -5%;
-ingcindezi yamanzi: okufanele ilungiswe ukuze kuzuzwe izinga elibekiwe lokulethwa;
-umnyombo womfudlana omkhulu: indilinga ecishe ibe ngu-40 mm ububanzi ebangeni elingu-2.5 m ukusuka emlonyeni;
-isikhathi sokuhlola imitha-skwele ngayinye yendawo ebiyelwe okungenzeka ifuthwe: 1 iminithi;
-imizuzu yokuhlola ihlala isikhathi eside: 3 min;
-ibanga ukusuka ku-nozzle kuya endaweni ebiyelwe: phakathi kuka-2.5 m no-3 m.
Okuphawuliwe:
Ama-trances amanzi awatholakalanga ngaphakathi kwendawo ebiyelwe ekupheleni kokuhlolwa kwe-iPX5.
Impahla esunguliwe ngeyomuntu osemthethweni: Longjoin.
Isikhathi sokuthumela: Jun-22-2020