JL-207C and JL-240TLXA IP65 Test Report

Test sample: photocontroller(JL-207C), rotate receptacle(JL-240TLXA)

Item No: JL-240TLXA, JL-207C

Rating: 480VAC, 15AMP

Test Requested: IPX5 test

Test Method (standards): according to client’s requirement and refer to IEC 60529+A11999+A2: 2013/EN 60529:1991+A1:200+A2:2013 clasuse 14.2.5

Testing Laboratory: SGS-CSTC Standards Technical Services(Shanghai) Co., Ltd.

Date test conducted: 2017-3-30 2017-4-1

Date of sample reception: 2017-03-30

The result: pass

Conclusion: the submitted sample comply with the requirements of IPX5

 

Ready Sample
SGS-IP65-test

Implement condition

SGS-Water Pressure Device

The test is made by spraying the enclosure from all practicable directions with a stream of water from a standard test nozzle as below experiment scenario figure.

SGS-test-condition

The condition to be observed are as follows:

-internal diameter of the nozzle: 6.3 mm;

-delivery rate :12.5 L/min +-5%;

-water pressure: to be adjusted to achieve the specified delivery rate;

-core of the substantial stream: circle of approximately 40 mm diameter at 2.5 m distance from nozzle;

-test duration per square metre of enclosure surface area likely to be sprayed: 1 min;

-minute test durable: 3 min;

-distance from nozzle to enclosure surface: between 2.5 m and 3 m.

SGS-IP65-after testc

Observations:

The water trances were not found inside enclosure at the end of iPX5 test.

Intellectual property belongs to legal person: Longjoin.

 


Post time: Jun-22-2020