Test sample: photocontroller(JL-207C), rotate receptacle(JL-240TLXA)
Item No: JL-240TLXA, JL-207C
Rating: 480VAC, 15AMP
Test Requested: IPX5 test
Test Method (standards): according to client’s requirement and refer to IEC 60529+A1:1999+A2: 2013/EN 60529:1991+A1:200+A2:2013 clasuse 14.2.5
Testing Laboratory: SGS-CSTC Standards Technical Services(Shanghai) Co., Ltd.
Date test conducted: 2017-3-30 2017-4-1
Date of sample reception: 2017-03-30
The result: pass
Conclusion: the submitted sample comply with the requirements of IPX5
Implement condition
The test is made by spraying the enclosure from all practicable directions with a stream of water from a standard test nozzle as below experiment scenario figure.
The condition to be observed are as follows:
-internal diameter of the nozzle: 6.3 mm;
-delivery rate :12.5 L/min +-5%;
-water pressure: to be adjusted to achieve the specified delivery rate;
-core of the substantial stream: circle of approximately 40 mm diameter at 2.5 m distance from nozzle;
-test duration per square metre of enclosure surface area likely to be sprayed: 1 min;
-minute test durable: 3 min;
-distance from nozzle to enclosure surface: between 2.5 m and 3 m.
Observations:
The water trances were not found inside enclosure at the end of iPX5 test.