JL-207C et JL-240TLXA IP65 Test Report

Testsample: photocontroller(JL-207C), receptaculum rotatum (JL-240TLXA)

Item No: JL-240TLXA, JL-207C .

Rating: 480VAC, 15AMP

Rogatus test: IPX5 test

Test Methodus (signa): secundum huius postulationem et refer ad IEC 60529+A1.1999+A2: 2013/EN 60529:1991+A1:200+A2:2013 clasuse 14.2.5

TestisLabortivum: SGS-CSTC Signa Technical Services (Shanghai) Co., Ltd.

Dies test deductus est: 2017-3-30 2017-4-1

Date ex specimen receptionis: 2017-03-30

Tet consequuntur: pass

ConclusionEt summitto sample IPX5 exigentias parere "

 

Paratus Sample
SGS-IP65-test

Effectum deducendi conditione

SGS aqua Pressura Fabrica

Expertus factus est saeptum ab omnibus practicis directionibus spargendo cum aquae rivo e norma testiculi colliculi ut infra experimentum missionis figurae.

SGS-test-condicione

Conditio servanda haec est:

diametri colli -interni: 6.3 mm longi;

- traditio rate: 12.5 L/min +-5%;

-water pressura: ad accommodandum ad consequi praefinitum partus rate;

-cor amnis substantialis: circulus circiter 40 mm diametri ad 2.5 m distantium a COLLUM;

-test durationem per quadratum metri clausurae superficiei areae asperso probabile: 1 min;

-minute test durabile: 3 min;

-distantia a COLLUM usque ad superficiem clausurae: inter 2.5 m et 3 m.

SGS-IP65-post testc

Observationes:

Excessus aquae intra clausuram in fine test iPX5 non inventae sunt.

Intellectualis proprietas legalis est personae: Longjoin.

 


Post tempus: Iun-22-2020